Description
Pramac PY000A000BG Automatic ATS Panel for 10.35 kVA Generators
The PY000A000BG Automatic ATS Panel for generators allows you to connect the generator set to the home electrical system so that it starts automatically in the event of a power outage. The ATS panel is compatible with the Pramac WX3200 ES and WX 6200 ES generators.
Features
• If the primary power source stops supplying power, the Pramac ATS automatically starts the generator. After approximately 1 minute, the ATS supplies power to the generator’s electrical load. If the main power source is restored, the ATS shuts down the generator after approximately 1 minute.
• The emergency stop button allows you to immediately shut down the generator and interrupt the battery charging function.
• Features indicator lights for mains power, generator, load, battery, and fault. Includes an ATS multi-pin connector and signal cable.
Technical Data
• Operating Voltage: 8–15 V DC.
• Rated Current of Single-Phase Contactor: 45 A.
• Rated Voltage of Single-Phase Contactor: 230 V.
• Rated Frequency: 50 Hz.
• Rated Power: 10.35 kVA.
• Battery Charger Output Voltage: 13.8 V DC.
• Charging Current: 1 A.
• Operating Temperature Range: -20°C to 70 °C.
• Input Protection: IP 20.
• Cable: 5 m.
Included
• ATS Panel.
• 5-meter ATS cable.
• Instructions.
Control Panel Accessories
• ATS - Automatic Transfer Switch: Thanks to the transfer switch, the WX generator automatically kicks in during a power outage, continuing to supply power to all the home’s loads. The connector allows the generator to be easily disconnected if it needs to be moved for other purposes.
• Features:
- Control panel.
- Interlocked contactors.
- Selector switch: AUTO / MANUAL. In “manual” mode, the panel does not control the generator, which can be disconnected or turned on without interfering with the panel or the loads to which it is connected.
- Emergency button.
- Battery charger.
- 5-meter cable with connector.
• Status indicators
- Utility Power LED: Mains power present.
- Generator LED: The generator is running.
- Load LED: The load is powered (by mains or generator).
- Battery LED: Battery is charged.
- Failure LED: Malfunction; the generator has not started.
Control panel dimensions
• Length: 410 mm.
• Width: 310 mm.
• Height: 180 mm.